Graco

REACTOR A-XP1/A-25

Reactor A-XP1 er en Graco-konstruert pumpe som gir deg påliteligheten du forventer på jobbsiden. Det opprettholder konsistent temperaturkontroll, selv når du sprøyter med maksimal strømningshastighet - noe som resulterer i bedre kvalitet på belegget.

Reactor A-XP1 Plural Component Proportioner
Maximum Fluid Working Pressure
24 MPa, 241 bar
Maximum Air Supply Pressure
0.9 MPa, 9 bar
Maximum Air Working Pressure
689 MPa, 6.9 bar
Pressure Ratio
35:1
Air consumption with 00 tip at 2000 psi stall pressure
0.9m³/min
Machine Maximum Power with hose
13,000 Watts
Amperage Requirement (Full Load Peak)*
56 amps @ 230 V, 1 Phase, 45 amps @ 230 V, 3 Phase, 26 amps @ 380 V, 3 Phase
Maximum Heater Fluid Temperature
88°C
Maximum Hose Fluid Temperature
82°C
Maximum Ambient Temperature
49°C
Maximum Output
1.5 gal/min at 2000 psi
Output Per Cycle (A and B)
0.094 ltr/cycle
Heater Power
10,200 Watts
Hose Power
2790 Watts
Sound Pressure (see NXT air motor manual)
70.2 dB(A)
Sound Power (see NXT air motor manual)
80.1 dB(A)
Viscosity Range
250–1500 centipoise (typical)
Maximum Fluid Inlet Pressure
2.1 MPa, 21 bar or 15% of output pressure
Fluid Inlet/Strainer Filter
20 mesh standard
Air inlet Filter Mesh
40 Micron
Component B (Resin) Inlet
3/4 npt(f) swivel
Component A (Isocyanate) Inlet
3/4 npt(f) swivel
Recirculation/Block Hose Connections
Iso (A) side: #5 JIC (m); Resin (B) side: #6 JIC (m)
Maximum Heated Hose Length ***
210 ft of 3/8 ID
Weight
140.6 kg
Wetted Parts
Carbon steel, stainless steel, chrome, aluminum, Fluoroelastomer, PTFE, nylon
Voltage Tolerance Range (50/60 Hz)
200–240 V ac Nominal, 1 Phase
195–253 V ac
200–240 V ac Nominal, 3 Phase Delta
195–253 V ac
350–415 V ac Nominal, 3 Phase Wye (200–240 V ac Line-to-Neutral)
338–457 V ac
*Full load amps with all devices operating at maximum capabilities with 210 ft (64.1 m) of hose.
***210 ft (64 m) of heated hose will produce the maximum allowable heat capacity. 310 ft (94 m) of heated hose may be used, but will have 25% less heat capacity.
Reactor A-XP1 Plural Component Proportioner
Maximum Fluid Working Pressure
24 MPa, 241 bar
Maximum Air Supply Pressure
0.9 MPa, 9 bar
Maximum Air Working Pressure
689 MPa, 6.9 bar
Pressure Ratio
35:1
Air consumption with 00 tip at 2000 psi stall pressure
0.9m³/min
Machine Maximum Power with hose
13,000 Watts
Amperage Requirement (Full Load Peak)*
56 amps @ 230 V, 1 Phase, 45 amps @ 230 V, 3 Phase, 26 amps @ 380 V, 3 Phase
Maximum Heater Fluid Temperature
88°C
Maximum Hose Fluid Temperature
82°C
Maximum Ambient Temperature
49°C
Maximum Output
1.5 gal/min at 2000 psi
Output Per Cycle (A and B)
0.094 ltr/cycle
Heater Power
10,200 Watts
Hose Power
2790 Watts
Sound Pressure (see NXT air motor manual)
70.2 dB(A)
Sound Power (see NXT air motor manual)
80.1 dB(A)
Viscosity Range
250–1500 centipoise (typical)
Maximum Fluid Inlet Pressure
2.1 MPa, 21 bar or 15% of output pressure
Fluid Inlet/Strainer Filter
20 mesh standard
Air inlet Filter Mesh
40 Micron
Component B (Resin) Inlet
3/4 npt(f) swivel
Component A (Isocyanate) Inlet
3/4 npt(f) swivel
Recirculation/Block Hose Connections
Iso (A) side: #5 JIC (m); Resin (B) side: #6 JIC (m)
Maximum Heated Hose Length ***
210 ft of 3/8 ID
Weight
140.6 kg
Wetted Parts
Carbon steel, stainless steel, chrome, aluminum, Fluoroelastomer, PTFE, nylon
Voltage Tolerance Range (50/60 Hz)
200–240 V ac Nominal, 1 Phase
195–253 V ac
200–240 V ac Nominal, 3 Phase Delta
195–253 V ac
350–415 V ac Nominal, 3 Phase Wye (200–240 V ac Line-to-Neutral)
338–457 V ac
*Full load amps with all devices operating at maximum capabilities with 210 ft (64.1 m) of hose.
***210 ft (64 m) of heated hose will produce the maximum allowable heat capacity. 310 ft (94 m) of heated hose may be used, but will have 25% less heat capacity.

Ønsker du mer infomasjon om REACTOR A-XP1/A-25?